The rule in plain words
For level of energy efficiency (EP score in kWh/m² of collateral) estimated: these twelve worked out cannot be negative:
- 0; <= 100 (under total EU area)
- > 100; <= 200 (under total EU area)
- > 200; <= 300 (under total EU area)
- > 300; <= 400 (under total EU area)
- > 400; <= 500 (under total EU area)
- > 500 (under total EU area)
- 0; <= 100 (under total non-EU area)
- > 100; <= 200 (under total non-EU area)
- > 200; <= 300 (under total non-EU area)
- > 300; <= 400 (under total non-EU area)
- > 400; <= 500 (under total non-EU area)
- > 500 (under total non-EU area)
How the Line4 Check report words itShowHide
Word for word as the report shows it when the rule fails.
Total EU area, of which Level of energy efficiency (EP score in kWh/m² of collateral) estimated, 0; <= 100 + Total EU area, of which Level of energy efficiency (EP score in kWh/m² of collateral) estimated, > 100; <= 200 + Total EU area, of which Level of energy efficiency (EP score in kWh/m² of collateral) estimated, > 200; <= 300 + Total EU area, of which Level of energy efficiency (EP score in kWh/m² of collateral) estimated, > 300; <= 400 + Total EU area, of which Level of energy efficiency (EP score in kWh/m² of collateral) estimated, > 400; <= 500 + Total EU area, of which Level of energy efficiency (EP score in kWh/m² of collateral) estimated, > 500 + Total non-EU area, of which Level of energy efficiency (EP score in kWh/m² of collateral) estimated, 0; <= 100 + Total non-EU area, of which Level of energy efficiency (EP score in kWh/m² of collateral) estimated, > 100; <= 200 + Total non-EU area, of which Level of energy efficiency (EP score in kWh/m² of collateral) estimated, > 200; <= 300 + Total non-EU area, of which Level of energy efficiency (EP score in kWh/m² of collateral) estimated, > 300; <= 400 + Total non-EU area, of which Level of energy efficiency (EP score in kWh/m² of collateral) estimated, > 400; <= 500 + Total non-EU area, of which Level of energy efficiency (EP score in kWh/m² of collateral) estimated, > 500 >= 0
What to do if your filing fails it
- 01Open the template below and find the cells the rule reads.
- 02Work out both sides from your file, as the rule in plain words sets out, and compare them.
- 03EBA allows a small rounding difference, worked out from the decimals each value is reported with.
- 04It runs only when your filing indicators mark D 02.00 as reported.
- 05This is a warning. It does not stop the filing on its own, but your authority may ask you to explain it.
The cells it reads
Rows
- 0050Of which Level of energy efficiency (EP score in kWh/m² of collateral) estimated
- 0100Of which Level of energy efficiency (EP score in kWh/m² of collateral) estimated
Columns
- 00200; <= 100
- 0030> 100; <= 200
- 0040> 200; <= 300
- 0050> 300; <= 400
- 0060> 400; <= 500
- 0070> 500
Show the rule as writtenShowHide
EBA's formula. Cells are written as {template, row, column, sheet}.
{D_02.00.a,r0050,c0020,} + {D_02.00.a,r0050,c0030,} + {D_02.00.a,r0050,c0040,} + {D_02.00.a,r0050,c0050,} + {D_02.00.a,r0050,c0060,} + {D_02.00.a,r0050,c0070,} + ({D_02.00.a,r0100,c0020,} + {D_02.00.a,r0100,c0030,} + {D_02.00.a,r0100,c0040,} + {D_02.00.a,r0100,c0050,} + {D_02.00.a,r0100,c0060,} + {D_02.00.a,r0100,c0070,}) >= 0Other rules on D 02.00.a
- An upper-limit check on banking book: Indicators of potential climate change transition risk (row 0050, v89280_m)Warning
- The sum of four cells cannot be negative (row 0050, v89282_m)Warning
- A sum of eight cells cannot be negative (row 0020, v89279_m)Warning
- The sum of four cells cannot be negative (row 0050, v89283_m)Warning
- An upper-limit check on banking book: Indicators of potential climate change transition risk (row 0020, v89278_m)Warning
- The sum of four cells cannot be negative (row 0050, v89284_m)Warning
- A sum of eight cells cannot be negative (row 0020, v89277_m)Warning
- The sum of 24 cells cannot be negative (v89285_m)Warning
Checks like this one, run at the point of submission, are the first step to real-time supervision.
