The rule in plain words
Commercial immovable property cannot be less than under construction / development.
EBA checks it for nine columns, from gross carrying amount (0010) to carrying amount (0130). That makes nine checks. A failure names the one that failed.
How the Line4 Check report words itShowHide
The first of its checks, word for word as the report shows it when it fails. The others read the same, with their own column, row or sheet.
Carrying amount: Commercial immovable property >= Of which: under construction / development
What to do if your filing fails it
- 01Open the template below and find the cells the rule reads.
- 02Compare the values in your file. If the first is smaller than it may be, one of them is wrong: check both before you change either.
- 03EBA allows a small rounding difference, worked out from the decimals each value is reported with.
- 04It runs only when your filing indicators mark F 25.02 as reported.
- 05This is a warning. It does not stop the filing on its own, but your authority may ask you to explain it.
The cells it reads
Rows
- 0030Commercial immovable property
- 0040Of which: under construction / development
Columns
- 0010Gross carrying amount
- 0030Value at initial recognition
- 0040Carrying amount
- 0060Value at initial recognition
- 0070Carrying amount
- 0090Value at initial recognition
- 0100Carrying amount
- 0120Value at initial recognition
- 0130Carrying amount
A worked example
The first of its checks, with simple numbers.
Under construction / development can then be at most 1,200.
A file that reports 1,200 passes. One that reports 1,300 fails, by 100.
The numbers are illustrative, reported to the unit, so the rounding tolerance does not change the result.
Show the rule as writtenShowHide
EBA's formula, as written out for the first of its checks. Cells are written as {template, row, column, sheet}.
{F_25.02.a,r0030,c0100,} >= {F_25.02.a,r0040,c0100,}The next five:
{F_25.02.a,r0030,c0120,} >= {F_25.02.a,r0040,c0120,}{F_25.02.a,r0030,c0030,} >= {F_25.02.a,r0040,c0030,}{F_25.02.a,r0030,c0130,} >= {F_25.02.a,r0040,c0130,}{F_25.02.a,r0030,c0060,} >= {F_25.02.a,r0040,c0060,}{F_25.02.a,r0030,c0070,} >= {F_25.02.a,r0040,c0070,}And 3 more, the same formula for the other cells it covers.
Other rules on F 25.02.a
- Commercial immovable property cannot be more than land related to commercial real estate corporations (excluding agricultural land) (v8085_m)Warning
- Commercial immovable property cannot be less than land related to commercial real estate corporations (excluding agricultural land) (v8087_m)Warning
- Commercial immovable property cannot be more than under construction / development (v8084_m)Warning
- Land related to commercial real estate corporations (excluding agricultural land) must equal the sum of its two parts (v8088_m)Warning
- Residential immovable property cannot be less than under construction / development (v8083_m)Warning
- Total must equal the sum of its five parts (v8089_m)Warning
- Residential immovable property cannot be more than under construction / development (v8082_m)Warning
- Accumulated negative changes, collateral obtained by taking possession other than collateral classified as property Plant and equipment (PP&E) must equal the sum of its three parts (v8081_m)Warning
Every FINREP 9 rule, by template
Checks like this one, run at the point of submission, are the first step to real-time supervision.
