1 min readWarningEBA reporting framework 4.2Updated 10 November 2026

None of the five values it checks in details on exposures in low default portfolios can be negative (C 113.00, EBA rule v09329_s)

A warning in the benchmarking of IFRS 9 models return (SBP IFRS 9), on template C 113.00, details on exposures in low default portfolios by counterparty by facility.

The rule in plain words

None of the values it checks in details on exposures in low default portfolios can be negative.

EBA checks it for five columns: exposure value, annualised originated PD, annualised PD at reporting date, quantitative Stage 2 trigger (in annualised PD) and low credit risk exemption threshold (if applicable). That makes five checks. A failure names the one that failed.

How the Line4 Check report words itShow

The first of its checks, word for word as the report shows it when it fails. The others read the same, with their own column, row or sheet.

Exposure value: Exposure value >= 0

What to do if your filing fails it

  1. 01Open the template below and find the cells the rule reads.
  2. 02Look for a value with the wrong sign in these cells, such as an amount entered as a negative number.
  3. 03EBA compares the values exactly here: there is no rounding tolerance.
  4. 04It runs only when your filing indicators mark C 113.00 as reported.
  5. 05This is a warning. It does not stop the filing on its own, but your authority may ask you to explain it.

The cells it reads

Details on exposures in low default portfolios by counterparty by facility (C 113.00)

Columns

  • 0100Exposure value
  • 0300Annualised originated PD
  • 0400Annualised PD at reporting date
  • 0500Quantitative Stage 2 trigger (in annualised PD)
  • 0550Low Credit Risk exemption threshold (if applicable)

A worked example

The first of its checks, with simple numbers.

What the rule then expects

Exposure value must then be at least 0.

0Passes
-100Fails

A file that reports 0 passes. One that reports -100 fails, by 100.

The numbers are illustrative.

Show the rule as writtenShow

EBA's formula, as written out for the first of its checks. Cells are written as {template, row, column, sheet}.

{C_113.00,,c0100,} >= 0

The next four:

{C_113.00,,c0300,} >= 0{C_113.00,,c0500,} >= 0{C_113.00,,c0550,} >= 0{C_113.00,,c0400,} >= 0

Every SBP IFRS 9 rule, by template