The rule in plain words
Amount must be less than 1.
EBA checks it for 24 rows, from CET1 capital ratio (0010) to total capital ratio without application of the transitional provisions on the output floor S-TREA (Article 465(3), (4), (5) and 7 of Regula (0380). That makes 24 checks. A failure names the one that failed.
How the Line4 Check report words itShowHide
The first of its checks, word for word as the report shows it when it fails. The others read the same, with their own column, row or sheet.
CET1 Capital ratio without application of the transitional provisions on the output floor S-TREA (Article 465 (3), (4), (5) and 7 of Regulat < 1
What to do if your filing fails it
- 01Open the template below and find the cells the rule reads.
- 02Look for a value outside the limit in these cells.
- 03If the value is a percentage, EBA expects it as a decimal: 12% is reported as 0.12.
- 04EBA allows a small rounding difference, worked out from the decimals each value is reported with.
- 05It runs only when your filing indicators mark C 03.00 as reported.
- 06This is a warning. It does not stop the filing on its own, but your authority may ask you to explain it.
The cells it reads
Capital adequacy - ratios (C 03.00)
Rows
- 0010CET1 Capital ratio
- 0030T1 Capital ratio
- 0050Total capital ratio
- 0070CET1 Capital ratio considering unfloored TREA
- 0080T1 Capital ratio considering unfloored TREA
- 0090Total capital ratio considering unfloored TREA
- 0130Total SREP capital requirement ratio (TSCR)
- 0140TSCR: to be made up of CET1 capital
- 0150TSCR: to be made up of Tier 1
- 0151Total SREP capital requirement (TSCR) ratio without cap of Article 104a(6), point (a), of Directive 2013/36/EU
- 0152TSCR: to be made up of CET1 capital
- 0153TSCR: to be made up of Tier 1 capital
- 0160Overall capital requirement ratio (OCR)
- 0170OCR: to be made up of CET1 capital
- 0180OCR: to be made up of Tier 1
- 0190OCR and Pillar 2 Guidance (P2G)
- 0200OCR and P2G: to be made up of CET1 capital
- 0210OCR and P2G: to be made up of Tier 1 capital
- 0330Fully loaded CET1 Capital ratio
- 0340Fully loaded T1 Capital ratio
- 0350Fully loaded Total capital ratio
- 0360CET1 Capital ratio without application of the transitional provisions on the output floor S-TREA (Article 465 (3), (4), (5) and 7 of Regulat
- 0370T1 Capital ratio without application of the transitional provisions on the output floor S-TREA (Article 465 (3), (4, (5) and 7 of Regulation
- 0380Total capital ratio without application of the transitional provisions on the output floor S-TREA (Article 465 (3), (4), (5) and 7 of Regula
Column
- 0010Amount
A worked example
The first of its checks, with simple numbers.
CET1 capital ratio without application of the transitional provisions on the output floor S-TREA (Article 465(3), (4), (5) and 7 of Regulat can then be anything less than 1.
A file that reports 0.9 passes. One that reports 1 fails.
The numbers are illustrative, reported with four decimals, so the rounding tolerance does not change the result.
Show the rule as writtenShowHide
EBA's formula, as written out for the first of its checks. Cells are written as {template, row, column, sheet}.
{C_03.00,r0360,c0010,} < 1The next five:
{C_03.00,r0180,c0010,} < 1{C_03.00,r0030,c0010,} < 1{C_03.00,r0070,c0010,} < 1{C_03.00,r0090,c0010,} < 1{C_03.00,r0330,c0010,} < 1And 18 more, the same formula for the other cells it covers.
Other rules on C 03.00
- If surplus or Deficit of CET1 capital is negative, CET1 capital ratio cannot be more than 0.045 (v6252_m)Blocking
- If CET1 capital ratio is at most 0.045, surplus or Deficit of CET1 capital must be negative (v6253_m)Warning
- If surplus or Deficit of T1 capital is negative, T1 capital ratio cannot be more than 0.06 (v6254_m)Blocking
- If T1 capital ratio is at most 0.06, surplus or Deficit of T1 capital cannot be more than zero (v6255_m)Warning
- If total capital ratio is at most 0.08, surplus or Deficit of total capital must be negative (v6256_m)Warning
- If surplus or Deficit of total capital is negative, total capital ratio cannot be more than 0.08 (v6257_m)Blocking
- Total SREP capital requirement ratio (TSCR) must be at least 0.08 (v6260_m)Warning
- TSCR: to be made up of CET1 capital must be at least 0.045 (v6261_m)Warning
Every COREP own funds rule, by template
Checks like this one, run at the point of submission, are the first step to real-time supervision.
